購買空(kong)氣源熱水器之后,安裝的(de)(de)時候一般都需(xu)要排(pai)(pai)掉水箱內的(de)(de)真空(kong),這樣能(neng)夠讓空(kong)氣(qi)能(neng)熱(re)水器得到更(geng)好的(de)(de)利(li)用,很多人都以為排(pai)(pai)空(kong)方法很難,其實很簡單(dan),哈思(si)為大家講解一下:
1,首先(xian)我們要卸掉空氣能熱水器主機三能截止閥上的排氣螺母;
2、連接真(zhen)空(kong)(kong)泵到空(kong)(kong)氣能(neng)(neng)熱泵主機(ji)的(de)三(san)通截止(zhi)閥上,真(zhen)空(kong)(kong)度抽(chou)到5pa左(zuo)右(you),等15分(fen)鐘,確定系統無泄漏(lou)后擰緊空(kong)(kong)氣能(neng)(neng)熱泵主機(ji)三(san)通截止(zhi)閥上的(de)排(pai)氣螺母。為保證抽(chou)真(zhen)空(kong)(kong)合(he)格(ge),抽(chou)空(kong)(kong)時間不要低于20分(fen)鐘。
3、卸掉空氣能熱泵主機(ji)上(shang)二(er)通(tong)(tong)(tong)截(jie)止閥(fa)和三(san)通(tong)(tong)(tong)截(jie)止閥(fa)的閥(fa)帽(mao);擰開(kai)二(er)通(tong)(tong)(tong)截(jie)止閥(fa)閥(fa)桿1/4圈,立即頂壓三(san)通(tong)(tong)(tong)截(jie)止閥(fa)的排氣頂針排氣8~10秒;用內六(liu)角扳手沿逆時(shi)針方(fang)向(xiang)轉動三(san)通(tong)(tong)(tong)截(jie)止閥(fa)的閥(fa)芯直至完全打(da)開(kai),重新蓋好二(er)通(tong)(tong)(tong)截(jie)止閥(fa)和三(san)通(tong)(tong)(tong)截(jie)止閥(fa)的閥(fa)帽(mao),并(bing)擰緊。
4、最后要(yao)檢(jian)漏(lou):用肥皂水(shui)等(deng)檢(jian)漏(lou)方法,檢(jian)查各管子連(lian)接處及各閥帽口,是否有泄漏(lou),若有,須用扳手擰緊至(zhi)不漏(lou),絕對不允許(xu)有泄漏(lou)現象。
保證在(zai)水箱(xiang)裝滿水而且排完(wan)空氣(qi)后才(cai)能(neng)夠開機。